Refrigeration Package Systems
| MINIFJORD 3 - Low capacity split system - click on link for details |
![]() |
MAXIBOREAL MAXIBOREAL is a split system specifically designed to offer you maximum comfort: accessibility to components, low noise option, oversized condenser block for hot countries…
Total control of production and numerous factory inspections ensure optimum operating reliability.
The 5 pre-selected applications are as follows:
|
CONDENSING UNIT • The condensing unit is housed for outdoor installation. Three compressor technologies are available: hermetic pistons, semihermetic pistons and Scroll. Each compressor is equipped with an oil sight glass, case heating element, suction and delivery valves. • LP regulation and HP safety are provided by factory-set pressure switches. • The vertical condenser is equipped with 1 to 4 fans depending on the model with different rotation speeds to suit various environmental conditions. • As standard, condensing pressure regulation is provided with variation of the fan speed or with the pressure switches depending on the model. • The liquid receiver is equipped with an outlet valve to isolate the liquid line composed of a filter drier cartridge, a sight glass and a manual shut-off valve. • The electrical enclosure is incorporated into the casing and the main circuit-breaker is protected in a case to avoid any damage during transport. • The unit is pre-charged with R404A refrigerant. UNIT COOLERS • Dual discharge evaporator, low noise level or cubic depending on the applications,with factory-fitted expansion device and solenoid valve. For further details, consult our commercial evaporators brochure. CONTROL • Electronic regulation. • Defrost control (air or electric). • Lighting control. • Display and transfer of alarms. • An additional programmable contact (door open, person inside enclosure safety switch...). • Built-in forced operation for fast cooling or freezing. |
![]() |
MONOHAVANE Designed to meet the needs of a wide range of commercial industrial cooling applications, the MONOHAVANE condensing unit line comprises capacities from 5 to 75 kW. These totally enclosed units are installed outdoors either on the ground or on the roof. The MONOHAVANE line offers a solution to noise problems (down to 39 dBA at 10 m with the low noise level option), and may be used under extreme outdoor temperature conditions. |
| CHASSIS / CASING • Painted sheet metal chassis with enamelled sheet metal casing. Installed outdoors on the ground or roof. COMPRESSOR • Semi-hermetic reciprocating (7.5 to 50 HP) with suction and delivery valves, crankcase heater and head cooling fan for negative applications. CONDENSER • Standard H5-H6 or H9 Standard with tube end protection casing. RECEIVER • With service and safety valves. LIQUID LINE • Includes of a filter drier cartridge, sight glass and a shutoff valve. REGULATION AND CONTROL • Assured by a HP pressure switch cartridge, an auto LP pressure switch, HP regulation and oil differential pressure switches. ELECTRICAL ENCLOSURE • Electrical enclosure: sealed, with circuit-breaker on the side and "power on" light indicator. Outputs and unit protection devices. Designed to accommodate as many cooling outputs as required. • The enclosure is closed with a 1/4-turn screw. Possibility to latch the door open during service. |